Free reference

PT norms and MCIDs

The numbers Clinic checks every measurement against. Each one sourced.

Outcome scores

The change that counts.

The MCID is the smallest change in a score that counts as real.

MeasureScaleMCIDSource
PSFSPatient-Specific Functional Scale. The patient's own three activities, any region.0–10, higher is better2Stratford 1995
NPRSNumeric Pain Rating Scale. Pain now, best and worst, 0 to 10.0–10, lower is better2Childs 2005
LEFSLower Extremity Functional Scale. Hip, knee, ankle and foot function.0–80, higher is better9Binkley 1999
KOOSKnee injury and Osteoarthritis Outcome Score. Knee pain, symptoms, daily living, sport and quality of life.0–100, higher is better8Roos 2008
FAAM-ADLFoot and Ankle Ability Measure, daily living. Foot and ankle function in daily living.0–100, higher is better8Martin 2005
QuickDASHArm, shoulder and hand disability, 11 items.0–100, lower is better16Franchignoni 2014
DASHDisabilities of the Arm, Shoulder and Hand. Arm, shoulder and hand disability, 30 items.0–100, lower is better10.8Beaton 2001
SPADIShoulder Pain and Disability Index. Shoulder pain and disability.0–100, lower is better8Roy 2009, who report 8 to 13
ODIOswestry Disability Index. Low back disability.0–100, lower is better10Ostelo 2008
NDINeck Disability Index. Neck disability.0–50, lower is better7Young 2009
BergBerg Balance Scale. Balance in 14 tasks.0–56, higher is better4Donoghue 2009, minimal detectable change

Clinic compares each score with the last one on the chart and says whether the change reaches the MCID. Berg's 4 points is a minimal detectable change, the figure its source gives. SPADI's source reports 8 to 13; Clinic uses 8. The ABC scale and APTA OPTIMAL carry no change threshold in Clinic, so none is printed here.

What each score means

Where a scale publishes bands, Clinic writes the band beside the score.

ODI %

ScoreBand
0–20Minimal disability
21–40Moderate disability
41–60Severe disability
61–80Crippled
81–100Bed-bound or exaggerating

Source: Fairbank 2000.

NDI of 50

ScoreBand
0–4No disability
5–14Mild disability
15–24Moderate disability
25–34Severe disability
35–50Complete disability

Source: Vernon 1991.

ABC %

ScoreBand
Under 50Low level of physical functioning
50–80Moderate level of physical functioning
Over 80High level of physical functioning

Source: Myers 1998.

Timed tests

Age norms and cutoffs.

Clinic writes the norm for the patient's age beside the time.

Timed Up and Go

Comfortable-speed TUG, community-dwelling older adults, by age. Seconds.

AgeMean, s95% CI, s
60–698.17.1–9.0
70–799.28.2–10.2
80–9911.310.0–12.7

Source: Bohannon 2006, J Geriatr Phys Ther 29:64, a meta-analysis.

  • 12 s is the CDC STEADI fall-risk cutoff.
  • 13.5 s or more is associated with falls (Shumway-Cook 2000, Phys Ther 80:896): sensitivity 0.87, specificity 0.87, in 30 older adults, 15 with no falls and 15 with two or more. A small sample.

Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the Timed Up & Go Test. Phys Ther. 2000;80(9):896-903. doi:10.1093/ptj/80.9.896

10-meter walk: gait speed

Comfortable walking speed by decade and sex. Meters per second.

AgeWomen, m/sMen, m/s
20–291.411.36
30–391.351.43
40–491.391.43
50–591.311.43
60–691.241.34
70–791.131.33

Source: Bohannon 1997, Age Ageing 26:15.

Speed, m/sWalking category
Under 0.4Household ambulator
0.4 to under 0.8Limited community ambulator
0.8 and overCommunity ambulator

Source: Perry 1995, Stroke 26:982.

  • Under 1.0 m/s is associated with worse health outcomes (Studenski 2011, JAMA 305:50).
  • 100–120 steps/min is typical healthy adult cadence (Perry and Burnfield 2010, Gait Analysis). With a step count, Clinic also writes cadence, step length and stride length from the same walk.

Five Times Sit to Stand

Time for five stands, by age. Seconds.

AgeMean, s95% CI, s
60–6911.49.7–13.1
70–7912.610.2–15.0
80–8914.812.7–16.9

Source: Bohannon 2006, Percept Mot Skills 103:215.

  • Over 15 s predicted recurrent falls (Buatois 2008, J Am Geriatr Soc 56:1575).

30-Second Chair Stand

Stands in 30 seconds. A score under the number shown is below average for age and sex, and goes with increased fall risk.

AgeWomen, underMen, under
60–641214
65–691112
70–741012
75–791011
80–84910
85–8988
90–9447

Source: CDC STEADI 30-Second Chair Stand (Rikli and Jones 1999).

Clinic reads the norm for the patient's age, and sex where the source splits by it; with no age on the chart it leaves the norm out instead of guessing. Values as KinematiX Clinic holds them on October 28, 2026. A reference, not a diagnosis: check the paper before you quote a number in a report. If one is wrong, write to brian@kinematix.app and we fix it.

Range of motion

Normal range, motion by motion.

38 motions, one adult value each. The camera measures the 12 marked ones.

How to read the tables

Normal is the American Academy of Orthopaedic Surgeons (AAOS) value for active motion with a universal goniometer, cross-checked against Norkin and White's Measurement of Joint Motion, or the AMA Guides value where AAOS gives none. AAOS tables differ by edition for several joints; where they disagree, the note under the table says which value Clinic uses.

Green, yellow and red are KinematiX's own clinical standard, set by Brian Jones, DPT, and not an AAOS figure. Green, within normal limits, is 95% of normal or more; yellow, within functional limits, is 75% up to green; red, below normal limits, is under 75%. The Green and Yellow columns give the degree each band starts at, rounded to the whole degree.

Lower extremity

Hip, knee, ankle and great toe.

MotionNormalGreenYellowSource
Hip flexionCamera measures it120°114°90°AAOS
Hip extensionCamera measures it30°29°23°AAOS, edition choice
Hip abductionCamera measures it40°38°30°AMA Guides
Hip adductionCamera measures it20°19°15°AMA Guides
Hip internal rotation45°43°34°AAOS
Hip external rotation45°43°34°AAOS
Knee flexionCamera measures it135°128°101°AAOS
Ankle dorsiflexionCamera measures it20°19°15°AAOS
Ankle plantarflexionCamera measures it50°48°38°AAOS
Great toe (1st MTP) extension70°67°53°AAOS
Great toe (1st MTP) flexion45°43°34°AAOS

Hip extension: AAOS tables list 20° or 30°; Clinic uses 30°, the value more commonly published. Hip abduction: AAOS tables commonly list 45°; Clinic keeps the AMA Guides 40°. Hip adduction: AAOS gives no value.

Upper extremity

Shoulder, elbow, forearm and wrist.

MotionNormalGreenYellowSource
Shoulder flexionCamera measures it180°171°135°AAOS
Shoulder extensionCamera measures it60°57°45°AAOS
Shoulder abductionCamera measures it180°171°135°AAOS
Shoulder adductionCamera measures it40°38°30°AMA Guides
Shoulder internal rotation70°67°53°AAOS
Shoulder external rotation90°86°68°AAOS
Elbow flexionCamera measures it150°143°113°AAOS
Forearm pronation80°76°60°AAOS
Forearm supination80°76°60°AAOS
Wrist flexion80°76°60°AAOS
Wrist extension70°67°53°AAOS
Wrist radial deviation20°19°15°AAOS
Wrist ulnar deviation30°29°23°AAOS

Shoulder adduction: AAOS gives no value.

Hand and fingers

Fingers 2nd to 5th, and the thumb.

MotionNormalGreenYellowSource
Finger MCP flexion90°86°68°AAOS
Finger PIP flexion100°95°75°AAOS
Finger DIP flexion90°86°68°AAOS
Thumb CMC abduction70°67°53°AAOS
Thumb MCP flexion50°48°38°AAOS
Thumb IP flexion80°76°60°AAOS

Spine, approximate

The method varies, and spine motion is far more variable than the limbs. Lateral flexion and rotation are each side.

MotionNormalGreenYellowSource
Cervical flexion45°43°34°AAOS
Cervical extension45°43°34°AAOS
Cervical lateral flexion45°43°34°AAOS
Cervical rotation80°76°60°AAOS, edition choice
Thoracolumbar flexion80°76°60°AAOS, degrees method
Thoracolumbar extension25°24°19°AAOS
Thoracolumbar lateral flexion35°33°26°AAOS
Thoracolumbar rotation45°43°34°AAOS

Cervical rotation: AAOS tables list 60° or 80°; Clinic uses 80°, the value more commonly published. Thoracolumbar flexion is the AAOS degrees method.

Knee and elbow extension are left off: their normal is 0°, so a percent of normal means nothing, and Clinic's reference table holds no band for them. These are healthy-adult values; after surgery, or for a given diagnosis, the target differs. A camera angle is an estimate, marked as one in the note, and you confirm the number. Values as KinematiX Clinic holds them on October 28, 2026.